Title of article :
Studies on flow instability of helical tube steam generator with Nyquist criterion
Author/Authors :
Niu، نويسنده , , Fenglei and Tian، نويسنده , , Li and Yu، نويسنده , , Yu and Li، نويسنده , , Rizhu and Norman، نويسنده , , Timothy L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
7
From page :
63
To page :
69
Abstract :
The steam generator of the 10 MW High Temperature Gas-Cooled Reactor (HTR-10) in China consists of a series of helical tubes where water/steam flows inside and helium flows outside. It operates under middle pressure, which tends to cause the flow instability. Density-wave oscillation is the most common type of two-phase flow instability in the steam generators. This paper presents the research on flow instability for the HTR-10 steam generator. The drift flux model was used for two-phase flow analysis. The transfer matrix was obtained by using linearized perturbation and Laplace transformation on the conservation equations. The flow stability was evaluated by the Nyquist stability criterion. The results obtained from frequency domain method were compared and discussed with the results from the time domain method and the experimental results.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2014
Journal title :
Nuclear Engineering and Design Eslah
Record number :
1593923
Link To Document :
بازگشت