Title of article :
High energy pipe break analysis for a Main Steam Line of a WWER NPP
Author/Authors :
Zaccari، نويسنده , , N. and Caria، نويسنده , , S. and Rubeo، نويسنده , , G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
The aim of this study is to show the application of the High Energy Pipe Break (HEPB) methodology to a level 3 analysis, applied to the study of the Main Steam Line (MSL) of a Mochovce (MO) NPP. The analysis highlighted the significant advantage, as compared to a standard level 1 analysis, in the minimization of extra supports and restraints. In the first part of the paper an introduction on the NUREG Standard Review Plan (STRP) and on the ANSI/ANS 58.2 used as a reference in this kind of analysis is provided. In the second part a description of the analyses (coupled mechanical and fluido-dynamic) used to analyze the HEPB is described. Finally an original approach developed at ENEL is presented for an improved evaluation of the leakage cracking by following a non standard procedure related to the LBB approach, coupled with the above-mentioned HEPB.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :
Nuclear Engineering and Design Eslah