Heat transfer of a helical double-pipe vertical evaporator: Theoretical analysis and experimental validation
Author/Authors :
Colorado-Garrido، نويسنده , , D. and Santoyo-Castelazo، نويسنده , , E. and Hernلndez، نويسنده , , J.A. and Garcيa-Valladares، نويسنده , , O. and Siqueiros، نويسنده , , J. and Juarez-Romero، نويسنده , , D.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
10
From page :
1144
To page :
1153
Abstract :
A predictive model is developed to describe heat transfer and fluid dynamic behavior of a helical double-pipe vertical evaporator used in an absorption heat transformer integrated to a water purification process. The evaporator uses water as working fluid connected in countercurrent. Heat transfer by conduction in the internal tube wall is considered; in addition the change of phase is carried out into the internal tube. The dynamic model considers equations of continuity, momentum and energy in each flow. The discretized governing equations are coupled using an implicit step by step method. The results of this model are compared with the experimental data in steady state, obtaining good agreement in the evaporation process. The model is also evaluated of form dynamic to determine the principal operation variables that affect the evaporator with the main objective to optimize and control the system.
Keywords :
heat transfer , Helical tube , Implicit method , Water purification , Heat transformer