Peak current mode control of three-phase boost rectifiers in discontinuous conduction mode for small wind power generators
Author/Authors :
Carranza، نويسنده , , O. and Garcerل، نويسنده , , G. and Figueres، نويسنده , , E. and Gonzلlez، نويسنده , , L.G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
9
From page :
2728
To page :
2736
Abstract :
This paper presents a peak current mode control scheme of a boost rectifier with low distortion of the input current for wind power systems based on permanent magnet synchronous generators with variable speed operation. The three-phase boost rectifier is operated in discontinuous conduction mode (DCM), and power factor correction techniques are applied. It is shown that the DCM operation significantly reduces the total harmonic distortion of the currents in the permanent magnet synchronous generator, increasing the power factor of the system, so that the vibrations and mechanical stress of the generator are minimized. The characteristics of the DCM boost rectifier are studied considering: (1) the series resistance of the inductors; (2) the modeling and adjustment of peak current mode control yielding a stable loop; (3) the design of an input filter that reduces the switching noise in the currents of the generator.
Keywords :
Wind generation systems , power factor correction , Harmonics
Journal title :
Applied Energy
Serial Year :
2010
Journal title :
Applied Energy
Record number :
1604320