Title of article
A modified model for estimation of daylight factor for skylight integrated with dome roof structure of mud-house in New Delhi (India)
Author/Authors
Chel، نويسنده , , Arvind K. Tiwari، نويسنده , , G.N. and Singh، نويسنده , , H.N.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
14
From page
3037
To page
3050
Abstract
The daylight factor model given by Charted Institute of Building Services Engineers (CIBSE) was modified in this paper to incorporate time variations with respect to zenith angle (θz) and vertical height (h) of working surface above ground surface which was normalized with central height (H) of skylight dome. The modified model contains constant exponents which are determined using linear regression analysis based on hourly experimental data of inside and outside illuminance for each month of the year 2007–2008. The prediction of modified model is found in good agreement with experimental observed inside illuminance data on the basis of values of root mean square percentage error (e) and correlation coefficient (r). The annual average daylight factor values for big and small dome skylight rooms are determined as 2.3% and 4.4% respectively. The energy saving potential of skylight rooms for selected climatic locations in India is also presented in this paper.
Keywords
illuminance , Skylight , Dome shape roof , Daylight factor , Mud-house