Title of article
Effects of individual climatic parameters on the infrared thermography of buildings
Author/Authors
Lehmann، نويسنده , , B. and Ghazi Wakili، نويسنده , , K. H. Frank، نويسنده , , Th. and Vera Collado، نويسنده , , B. and Tanner، نويسنده , , Ch.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
15
From page
29
To page
43
Abstract
Infrared thermography is an affordable, fast and hence widespread method to detect temperature distributions on the external surfaces of buildings. The interpretation of obtained thermal images requires the knowledge of the status of a multitude of climatic parameters preceding the thermography investigation. The length of the adequate time interval back in the climatic history depends on the thermal properties of the investigated building façade. Based on thermography of an old building with insulated and non-insulated façades, equipped with temperature sensors and a nearby meteo station, a numerical study has been carried out to quantify the individual influence of parameters such as air and sky temperature, wind, solar irradiation, thermal transmittance (U-value) and emissivity on the evaluation of thermal images. Subsequently, an in-depth numerical study is carried out to determine the minimum climatic history needed to correctly interpret the thermal images of various constructions having different thermal performance characteristics.
Keywords
Thermal transmittance , Solar irradiation , Infrared thermography , Sky temperature , Wind velocity , Climatic history
Journal title
Applied Energy
Serial Year
2013
Journal title
Applied Energy
Record number
1606399
Link To Document