Title of article :
Damaged masonry walls in two-way bending retrofitted with vertical FRP strips
Author/Authors :
Willis، نويسنده , , C.R. and Yang، نويسنده , , Q. and Seracino، نويسنده , , Jan R. and Griffith، نويسنده , , M.C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
14
From page :
1591
To page :
1604
Abstract :
Unreinforced masonry (hereafter termed ‘masonry’) structures comprise a significant proportion of the building stock in many countries worldwide, however their walls do not behave well under out-of-plane loading, such as that experienced during seismic events. Consequently, many existing masonry structures require some form of retrofit to comply with existing codes. As part of ongoing research at The University of Adelaide on the out-of-plane bending behaviour of masonry walls, eight full-scale walls (with window openings) were tested under reversed-cyclic loading. Four of the severely damaged walls were subsequently retrofitted using externally bonded (EB) (three walls) and near-surface mounted (NSM) (one wall) fibre-reinforced polymer (FRP) strips and tested again to quantify the increase in strength and ductility relative to the original capacities. A debonding mechanism not yet quantified for retrofitted masonry walls was observed and identified as displacement induced (DI) debonding. It is a result of a differential out-of-plane displacement at either side of a crack in the wall. NSM strips are more susceptible due to their orientation. This paper presents the results of the wall tests along with detailed accounts of the wall failure modes.
Keywords :
Fibre-reinforced polymer , Unreinforced masonry , out-of-plane , walls , Experimentation
Journal title :
Construction and Building Materials
Serial Year :
2009
Journal title :
Construction and Building Materials
Record number :
1629291
Link To Document :
بازگشت