Title of article :
Fire-resistance property of reinforced lightweight aggregate concrete wall
Author/Authors :
Go، نويسنده , , Cheer-Germ and Tang، نويسنده , , Jun-Ren and Chi، نويسنده , , Jen-Hao and Chen، نويسنده , , Cheng-Tung and Huang، نويسنده , , Yue-Lin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
This research focuses on reinforced lightweight aggregate concrete walls. After performing a standard temperature rising fire-resistance test, the fire resistance performance and mechanic behavior of the wall sample are studied under a lateral horizontal load. Reinforced lightweight aggregate concrete walls and reinforced normalweight concrete walls are given the fire-resistance test under the same conditions, then their fire resistance performance and mechanical behaviors are compared. Taking into consideration the steel spacing, aggregate type, wall size, and high temperature as the wall sample variables.
search results showed that the reinforced lightweight aggregate concrete wall is superior to the reinforced normalweight concrete wall on ultimate load, yield load, cracked load, stiffness, ductility, and inter-story drift after a high-temperature fire-resistance test. In terms of failure patterns, for a reinforced lightweight aggregate concrete wall after a high-temperature fire-resistance test, the smaller the steel spacing the higher the yield load and ultimate load, but the worse the ductility. This result matched the results of the reinforced lightweight aggregate concrete wall without the high-temperature fire-resistance test and revealed that the reinforced lightweight aggregate concrete wall retained its mechanics after the fire-resistance test.
Keywords :
Reinforced normalweight aggregate concrete wall , Fire-resistance test , Cracked load , Stiffness , ductility , Inter-story drift , Mechanics behavior , Reinforced lightweight aggregate concrete wall
Journal title :
Construction and Building Materials
Journal title :
Construction and Building Materials