• Title of article

    Effect of temperature on the early-stage hydration characteristics of Portland cement: A large-volume calorimetric study

  • Author/Authors

    Z?koutsk?، نويسنده , , Jan and Tydlit?t، نويسنده , , Vratislav and ?ern?، نويسنده , , Robert، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    8
  • From page
    969
  • To page
    976
  • Abstract
    A large-volume isothermal heat flow calorimeter is applied for determination of the specific hydration heat power, N, and specific hydration heat, Q, of Portland cement CEM I 42.5 R as a function of time. The measurements are carried out for the cement paste with w/c = 0.3, 0.35, and 0.4 in the temperature range of 5–30 °C. Experimental results show that Q in the initial hydration phase (including C3A hydration and the dormant period up to the first local minimum on the N(t) curve) decreases two times when the temperature increases from 5 °C to 30 °C, and it is independent of w/c within the studied range. The second local maximum on the N(t) curve (corresponding to the C3S hydration phase) is four to five times higher for 30 °C as compared with 5 °C, and it decreases up to 20% with increasing w/c; the time of its appearance is three times lower for 30 °C than 5 °C, and it is also independent of w/c. The apparent activation energy of the CEM I 42.5 R hydration is found independent of w/c within the analyzed range, its average value being 32.2 kJ/mol.
  • Keywords
    Isothermal heat flow calorimeter , cement paste , Temperature , w/c , Apparent activation energy , Hydration heat
  • Journal title
    Construction and Building Materials
  • Serial Year
    2012
  • Journal title
    Construction and Building Materials
  • Record number

    1634064