Title of article
Diagonal tension strength of vintage unreinforced clay brick masonry wall panels
Author/Authors
Dizhur، نويسنده , , D. and Ingham، نويسنده , , J.M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
10
From page
418
To page
427
Abstract
An experimental program was implemented where wall panels were obtained from two existing vintage unreinforced clay brick masonry (URM) buildings and subjected to a diagonal compression loading condition in order to induce a diagonal tension failure mode. The principal aims of the experimental program were to establish the diagonal tension strength of the vintage clay brick URM walls present in the two buildings and to establish a benchmark mortar mix suitable for use when manufacturing replica clay brick test assemblages that adequately represent the strength characteristics present in vintage URM buildings. It was concluded that the use of recycled clay bricks acquired from vintage URM buildings and a mortar mix of 1:2:9 (cement:lime:sand) appropriately replicates the material strength characteristics that are present in existing vintage clay brick URM buildings located in New Zealand.
Keywords
Unreinforced masonry , shear , Diagonal testing , in situ testing , in-plane
Journal title
Construction and Building Materials
Serial Year
2013
Journal title
Construction and Building Materials
Record number
1635023
Link To Document