Title of article :
Influence of silica fume and metakaolin with two different types of interfacial adhesives on the bond strength of repaired concrete
Author/Authors :
Mohammadi، نويسنده , , Masih and Mir Moghtadaei، نويسنده , , Reza and Ashraf Samani، نويسنده , , Nasibe، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
In this article, the factors affecting the bond strength are studied through slant shear tests made on 168 samples in two phases. Effects of silica fume (SF) and two types of metakaolin (MA, MB) replacement with a portion of cement in concrete repair are studied as the first phase. The second phase consists of plain cement slurry (PCS) and bonding slurry (BS) as the interfacial adhesives. Only metakaolin type B could improve the bond strength, and best results were obtained in PCS applied specimens. Applying BS in concrete repairs exposed to the water was not suitable to be used as an interfacial adhesive. In applying pozzolan the sort of interfacial adhesive in addition to the chemical components of the pozzolan must be considered.
Keywords :
Bond strength , Slant shear , silica fume , Metakaolin , Interfacial adhesive
Journal title :
Construction and Building Materials
Journal title :
Construction and Building Materials