Title of article :
Calibration of analytical formulations predicting compressive strength in consolidated three-leaf masonry walls
Author/Authors :
Silva، نويسنده , , Bruno and Pigouni، نويسنده , , Aikaterina Evina and Valluzzi، نويسنده , , Maria Rosa and Modena، نويسنده , , Claudio، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
11
From page :
28
To page :
38
Abstract :
This paper presents calibration of analytical models to predict the compressive strength of three-leaf stone masonry before and after consolidation with grout injection. Experimental results from previous campaigns were used, both published (Vintzileou and Tassios, 1995; Valluzzi et al., 2004; Vintzileou and Miltiadou-Fezans, 2008; Mazzon, 2010) [1–4] and from recent laboratory experiments at the University of Padova. As part of the present research work, three-leaf stone masonry panels in 1:1 and 2:3 scales, both in their original condition and consolidated with natural hydraulic lime-grout injections, were tested under monotonic and cyclic simple compression (Silva, 2012; Silva et al., 2014a,b) [5–7]. ork focuses on providing a data-enriched formula based on previous proposals by (Vintzileou and Tassios, 1995; Valluzzi et al., 2004; Vintzileou, 2007) [1, 2, 8] and also compiled in (Vintzileou, 2011) [9] to predict the compressive strength of three-leaf stone masonry before and after consolidation, together with analyses of the exploitation ranges of the formulations and grout compatibility. The effects of the reduced scale were also taken into account in the updated formulations.
Keywords :
Multi-leaf stone masonry , Grout injection , NHL , compression tests , Calibration , Analytical formulations
Journal title :
Construction and Building Materials
Serial Year :
2014
Journal title :
Construction and Building Materials
Record number :
1637037
Link To Document :
بازگشت