• Title of article

    Behaviour of steel moment connections with a single flange rib

  • Author/Authors

    Chen، نويسنده , , Cheng-Chih and Lee، نويسنده , , Jen-Ming and Lin، نويسنده , , Ming-Chih، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    10
  • From page
    1419
  • To page
    1428
  • Abstract
    This paper presents a study of flange rib moment connections for use in steel moment-resisting frames. The connections are strengthened by welding a vertical rib to the beam flange and the column flange. The rib is characterized by an extension. Finite element analysis and experiments were conducted to elucidate the behaviour of lengthened rib reinforced connections. The results of the finite element analysis established the effectiveness of the lengthened rib in mitigating local stress concentrations and forming the plastic hinge zone in the beam. Two full-scale proof-test specimens behaved as observed by the analysis, and exhibited greater than 3% radians of plastic rotation under cyclic load. Without brittle fracture, both specimens developed a plastic hinge in the beam. Extensive yielding and local buckling occurred in the beam flanges and the web. The connections strengthened with a single flange rib were successfully verified by the test.
  • Keywords
    CONNECTION , Flange rib , Plastic rotation
  • Journal title
    Engineering Structures
  • Serial Year
    2003
  • Journal title
    Engineering Structures
  • Record number

    1639477