Title of article
Sol–gel-derived amperometric biosensor for hydrogen peroxide based on methylene green incorporated in Nafion film
Author/Authors
Wang، نويسنده , , Bingquan and Dong، نويسنده , , Shaojun، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2000
Pages
8
From page
565
To page
572
Abstract
A hydrogen peroxide biosensor was fabricated by coating a sol–gel–peroxidase layer onto a Nafion-methylene green modified electrode. Immobilization of methylene green (MG) was attributed to the electrostatic force between MG+ and the negatively charged sulfonic acid groups in Nafion polymer, whereas immobilization of horseradish peroxidase was attributed to the encapsulation function of the silica sol–gel network. Cyclic voltammetry and chronoamperometry were employed to demonstrate the feasibility of electron transfer between sol–gel-immobilized peroxidase and a glassy carbon electrode. Performance of the sensor was evaluated with respect to response time, sensitivity as well as operational stability. The enzyme electrode has a sensitivity of 13.5 μA mM−1 with a detection limit of 1.0×10−7 M H2O2, and the sensor achieved 95% of the steady-state current within 20 s.
Keywords
Amperometric biosensor , Sol–gel , Nafion , Horseradish peroxidase , Methylene green
Journal title
Talanta
Serial Year
2000
Journal title
Talanta
Record number
1639969
Link To Document