Title of article :
Minimization of lead and copper interferences on spectrophotometric determination of cadmium using electrolytic deposition and ion-exchange in multi-commutation flow system
Author/Authors :
Gomes Neto، نويسنده , , José A and Oliveira، نويسنده , , Adriana P and Freshi، نويسنده , , Gian P.G and Dakuzaku، نويسنده , , Carolina S and de Moraes، نويسنده , , Mercedes، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2000
Pages :
7
From page :
497
To page :
503
Abstract :
A new strategy for minimization of Cu2+ and Pb2+ interferences on the spectrophotometric determination of Cd2+ by the Malachite green (MG)–iodide reaction using electrolytic deposition of interfering species and solid phase extraction of Cd2+ in flow system is proposed. The electrolytic cell comprises two coiled Pt electrodes concentrically assembled. When the sample solution is electrolyzed in a mixed solution containing 5% (v/v) HNO3, 0.1% (v/v) H2SO4 and 0.5 M NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. After electrolysis, the remaining solution passes through an AG1-X8 resin (chloride form) packed minicolumn in which Cd2+ is extracted as CdCl42−. Electrolyte compositions, flow rates, timing, applied current, and electrolysis time was investigated. With 60 s electrolysis time, 0.25 A applied current, Pb2+ and Cu2+ levels up to 50 and 250 mg l−1, respectively, can be tolerated without interference. For 90 s resin loading time, a linear relationship between absorbance and analyte concentration in the 5.00–50.0 μg Cd l−1 range (r2=0.9996) is obtained. A throughput of 20 samples per h is achieved, corresponding to about 0.7 mg MG and 500 mg KI and 5 ml sample consumed per determination. The detection limit is 0.23 μg Cd l−1. The accuracy was checked for cadmium determination in standard reference materials, vegetables and tap water. Results were in agreement with certified values of standard reference materials and with those obtained by graphite furnace atomic absorption spectrometry at 95% confidence level. The R.S.D. for plant digests and water containing 13.0 μg Cd l−1 was 3.85% (n=12). The recoveries of analyte spikes added to the water and vegetable samples ranged from 94 to 104%.
Keywords :
Spectrophotometry , Cadmium , Electrolytic deposition , Malachite green , Flow Analysis , Solid phase extraction
Journal title :
Talanta
Serial Year :
2000
Journal title :
Talanta
Record number :
1640870
Link To Document :
بازگشت