Title of article :
Separation of Cr(III) and Cr(VI) in river and reservoir water with 8-hydroxyquinoline immobilized polyacrylonitrile fiber for determination by inductively coupled plasma mass spectrometry
Author/Authors :
Wen، نويسنده , , Bei-bei Shan، نويسنده , , Xiao-Quan and Lian، نويسنده , , Jun، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2002
Pages :
7
From page :
681
To page :
687
Abstract :
A rapid and simple method has been developed for the separation of chromium (III) and Cr(VI) species in river and reservoir water. Chromium (III) can be chelated with 8-hydroxyquinoline immobilized polyacrylonitrile (PAN) fiber, whereas Cr(VI) cannot. Chelated Cr(III) can be eluted with 2 mol l−1 HCl–0.1 mol l−1 HNO3. Cr(VI) in the filtrate and Cr(III) in the eluant were determined by inductively coupled plasma mass spectrometry. The effect of pH, sample flow rate, eluant type and its volume on the concentration effectiveness of Cr(III) was investigated. The recommended method has been applied for the separation and determination of Cr(III) and Cr(VI) in river and reservoir water. The results indicated that the recovery of each individual Cr species ranged from 96 to 107% and the R.S.D. were found to be <10% at the level of ng ml−1. The effect of HNO3 added in the sampling procedure was also evaluated.
Keywords :
inductively coupled plasma mass spectrometry , River and reservoir water , 8-Hydroxyquinoline immobilized polyacrylonitrile fiber , Chromium(III) , Chromium(VI)