Title of article :
Determination of lead and cadmium in titanium dioxide by differential pulse anodic stripping voltammetry
Author/Authors :
Panigati، نويسنده , , Monica and Piccone، نويسنده , , Maria and DʹAlfonso، نويسنده , , Giuseppe and Orioli، نويسنده , , Marica and Carini، نويسنده , , Marina، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2002
Abstract :
A procedure for the simultaneous determination of lead and cadmium in TiO2 by differential pulse anodic stripping voltammetry (ASV) has been developed. The key feature of the method is the use of triethanolamine (TEA) to remove titanium interference: TiO2 undergoes acidic digestion with HF/H2SO4 at atmospheric pressure, TEA is added to the HCl solution of the residue and the solution is analysed using a standard ASV instrumentation, equipped with a hanging mercury drop electrode. The calibration curves for both lead and cadmium are linear up to 50 μg l−1 of solution, and the detection limits are 1 μg l−1, corresponding to 1 μg g−1 of TiO2. Method reliability was tested by comparing the results with those given by electrothermal atomic absorption spectroscopy. The method has been successfully applied for determination of both contaminants in powdered titanium dioxide (raw materials) and in titanium dioxide-containing cosmetics (sunscreen products).
Keywords :
Titanium dioxide , Anodic stripping voltammetry , Lead determination , Cosmetics