• Title of article

    Structural performance of a post-tensioned concrete floor during horizontally travelling fires

  • Author/Authors

    Ellobody، نويسنده , , E. and Bailey، نويسنده , , C.G.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    10
  • From page
    1908
  • To page
    1917
  • Abstract
    This paper highlights the structural performance of a bonded post-tensioned concrete floor subject to fires that travel horizontally between zones within the floorplate. The floorplate was previously analysed by the authors based on experimental and numerical investigations on one-way spanning bonded post-tensioned concrete slab strips. In the previous studies, a nonlinear finite element model was developed for the floor that considered the mechanical and thermal material nonlinearities of the floor’s components, interfaces between the components, different natural fire severities, different applied static load during the fire and different restraint conditions. The previous studies highlighted the importance of investigating the whole-building behaviour and provided a useful insight into the temperature distribution throughout the floor slab, failure modes, comparisons with current design rules and time–displacement behaviour of the floor under fire conditions. This paper extends the previous studies and uses the validated finite element model to investigate different horizontal travelling fire scenarios between zones and different inter-zone time delays to represent fire travelling time. The time–temperature distribution throughout the floor slab was predicted at different locations in the floor subject to travelling fires. Furthermore, the time–deflection and time–axial displacement relationships were predicted at different locations in the floor. The current study has shown that horizontally travelling fire scenarios and the inter-zone time delay affect the time–deflection behaviour considerably. The change in heating/cooling scenarios between zones has resulted in a cyclic deflection pattern, which has previously not been considered when designing post-tensioned concrete floors against fire. Based on the analysis of the results presented, it is shown that the worst case in terms of maximum vertical defection or maximum residual deflection, at a given point in the floorplate, could occur either under the assumption of a uniform fire or a travelling fire. It is therefore recommended that designers should consider the integrity of floorplates using various travelling fires.
  • Keywords
    Bonded tendons , fire tests , Modelling , Travelling fire , Post-tensioned concrete floors
  • Journal title
    Engineering Structures
  • Serial Year
    2011
  • Journal title
    Engineering Structures
  • Record number

    1645960