Title of article
Calculation of guyed masts in accordance with EN 1993-3-1 standard taking into account mast shaft geometrical imperfections
Author/Authors
Matuszkiewicz، نويسنده , , Monika، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
5
From page
2044
To page
2048
Abstract
Selected problems concerning designing of guyed masts with lattice shaft in accordance with the “EN 1993-3-1: Design of steel structures. Part 3-1: Towers, masts and chimneys–Towers and masts” European standard have been described in this paper. The method of application of the mast shaft geometrical imperfections in calculations has been discussed. Based on the performed comparative analysis of a certain mast, the influence of such imperfections on the ultimate values of internal forces in the mast shaft has been demonstrated.
Keywords
Guyed mast , Wind load , static analysis , Geometric Imperfections