Title of article :
Cyclic behavior of prefabricated circular composite columns with low steel ratio
Author/Authors :
Shim، نويسنده , , Chang Su and Chung، نويسنده , , Young Soo and Yoon، نويسنده , , Jae-Young، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
10
From page :
2525
To page :
2534
Abstract :
Improved economy and speed of construction can be achieved through the use of prefabricated structural members. As a step toward the advancement of prefabricated substructures, a precast composite column for seismic regions is proposed in this paper. Concrete-encased composite columns with core structural steel can be utilized for a fast construction method using steel connections. Six concrete-encased composite specimens with low steel ratio were fabricated. Quasi-static tests were conducted to investigate the cyclic response of the prefabricated composite columns. For composite columns with bolt connections, the cyclic behavior in terms of ultimate load and post-cracking behavior was enhanced significantly as the transverse reinforcement ratio increases. Higher prestressing gave greater flexural strength to the composite columns with prestressing and better energy absorption capacity, while displacement ductility of the prestressed composite column was decreased as the prestressing increased.
Keywords :
Bolt connection , Precast composite column , displacement ductility , prestress , Energy absorption , Ultimate strength
Journal title :
Engineering Structures
Serial Year :
2011
Journal title :
Engineering Structures
Record number :
1646089
Link To Document :
بازگشت