Title of article
Probabilistic evaluation of the design development length of a GFRP rod pull-out from concrete
Author/Authors
He، نويسنده , , Zheng and Tian، نويسنده , , Guo-Wen، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
10
From page
2943
To page
2952
Abstract
With an additional target reliability index of 1.098, the Rackwitz–Fiessler method was used to evaluate the coefficients associated with the design development length of a GFRP rod in concrete in the case of pull-out bond failures. As a result of the evaluation, the coefficients are proposed to be 0.0816 and 0.0933 for ordinary and aggressive exposures, respectively. The coefficient of variation of GFRP strength could exert the most significant influence on averaged coefficients. The effects of diameter and GFRP average strength greater than 750 MPa are found to be negligible. A linear relationship between the averaged coefficient and additional target reliability could be employed for developing a performance-based bond design methodology. With the combination of flexural analysis, the proposed relationship between the averaged coefficient and the so-called strength utilization factor could be applied to for the determination of a customized design development length of a GFRP rod in concrete.
Keywords
Fiber reinforced polymer rod , GLASS , Bond , Concrete , pull-out , Design development length , reliability analysis , reliability index
Journal title
Engineering Structures
Serial Year
2011
Journal title
Engineering Structures
Record number
1646186