Title of article
Studies on failure of transmission line towers in testing
Author/Authors
Prasad Rao، نويسنده , , N. and Samuel Knight، نويسنده , , G.M. and Mohan، نويسنده , , S.J. and Lakshmanan، نويسنده , , N.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
16
From page
55
To page
70
Abstract
The towers are vital components of the transmission lines and hence, accurate prediction of their failure is very important for the reliability and safety of the transmission system. When failure occurs, direct and indirect losses are high, leaving aside other costs associated with power disruption and litigation. Different types of premature failures observed during full scale testing of transmission line towers at Tower Testing and Research Station, Structural Engineering Research Centre, Chennai are presented. Failures that have been observed during testing are studied and the reasons discussed in detail. The effect of non-triangulated hip bracing pattern and isolated hip bracings connected to elevation redundant in ‘K’ and ‘X’ braced panels on tower behaviour are studied. The tower members are modeled as beam column and plate elements. Different types of failures are modeled using finite element software and the analytical and the test results are compared with various codal provisions. The general purpose finite element analysis program NE-NASTRAN is used to model the elasto-plastic behaviour of towers. Importance of redundant member design and connection details in over all performance of the tower is discussed.
Keywords
Transmission line towers , Tower testing , redundant , Hip bracing , Bearing failure , NON-LINEAR ANALYSIS
Journal title
Engineering Structures
Serial Year
2012
Journal title
Engineering Structures
Record number
1646526
Link To Document