Title of article
Ductility of slender reinforced concrete columns under monotonic flexure and constant axial load
Author/Authors
Barrera، نويسنده , , A.C. and Bonet، نويسنده , , J.L and Romero، نويسنده , , M.L. and Fernلndez، نويسنده , , M.A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
15
From page
398
To page
412
Abstract
In this paper an investigation is presented based on tests results of reinforced concrete columns subjected to monotonic flexure and constant axial load from a previous paper [1]. The variables of the tests were strength of concrete (30, 60 and 90 MPa), shear span ratio (M/(V · h) = 7.5, 10.5 and 15), axial load level (0–45%), and transversal and longitudinal reinforcement ratio (1.4–3.2%). This paper is a continuation of the aforementioned but focuses on the deformation capacity, which depends on the method selected to idealize the response diagram comparing four of these methods. The results show that the parameters affecting ductility are greatly influenced by the different methods. It was observed that the ductility in displacements does not always decrease with axial load and column slenderness. In addition, a new equation is proposed to obtain the ultimate displacement for slender columns.
Keywords
Curvature ductility , Slender column , Plastic length , Effective flexural rigidity , displacement ductility
Journal title
Engineering Structures
Serial Year
2012
Journal title
Engineering Structures
Record number
1647039