Title of article :
Buckling of parabolic arches with hangers and tie
Author/Authors :
Palkowski، نويسنده , , Szymon، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
5
From page :
128
To page :
132
Abstract :
This paper pertains to the critical load for two-hinged parabolic arches with hangers and tie. It was proved that the existence of hangers (vertical and especially slant) can lead to a significant increase of arch critical load and consequently to increase of arch capacity. It has also been shown that the convex distribution of ties (in relation to the horizontal tie) can often be very useful. The tabulated results presented in the paper allow to determine the effective (buckling) length of the arches. Furthermore, it has been noted that the recommendations of European Standard (Eurocode 3: EN 1993-2) concerning the buckling of parabolic arches with hangers and tie may quite frequently lead to unsafe design. The issues of buckling of arches presented in this paper have a practical aspect and, in author’s opinion, can find a direct application in design practice.
Keywords :
Arch with hangers and tie , Critical load , Effective Length , Buckling factor
Journal title :
Engineering Structures
Serial Year :
2012
Journal title :
Engineering Structures
Record number :
1647378
Link To Document :
بازگشت