• Title of article

    An improved criterion for sufficiently/insufficiently FRP-confined concrete derived from ultimate axial stress

  • Author/Authors

    Hu، نويسنده , , Bo، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    16
  • From page
    431
  • To page
    446
  • Abstract
    This paper presents the assessment results of existing criteria for sufficiently/insufficiently fiber-reinforced polymer (FRP)-confined concrete, develops a unified ultimate axial stress model and proposes an improved criterion. The existing criteria for FRP-confined concrete in circular and rectangular columns are reviewed. A large database has been established by collecting the available experimental results from the open literature for evaluation of the existing criteria. The assessment results indicate that there is still room for improvement in the existing criteria, especially in those for rectangular specimens. An improved criterion for FRP-confined concrete in both circular and rectangular columns is proposed on the basis of the existing criteria and deduced from the unified ultimate axial stress model which is developed in this paper as well. Comparisons between the criterion predictions and the test results demonstrate the accuracy of the proposed criterion.
  • Keywords
    fiber reinforced polymer , Concrete , Criteria , Insufficient confinement , Sufficient confinement
  • Journal title
    Engineering Structures
  • Serial Year
    2013
  • Journal title
    Engineering Structures
  • Record number