Title of article :
Flow injection potentiometric determination of clobutinol hydrochloride
Author/Authors :
Issa، نويسنده , , Y.M. and Zayed، نويسنده , , S.I.M.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2006
Pages :
7
From page :
481
To page :
487
Abstract :
New clobutinol (Clob) ion-selective polyvinyl chloride (PVC) membrane electrodes, based on the ion-associates of Clob with phosphotungstic acid or phosphomolybdic acid were prepared using dibutyl phthalate as plasticizing solvent. The electrodes were characterized in terms of membrane composition, temperature and pH. The sensors showed a near-Nernstian response over the concentration ranges (6.31 × 10−6)–(1.00 × 10−2) and (5.01 × 10−5)–(1.00 × 10−2) M in the case of clobutinol-phosphotungstate ((Clob)3-PT) applying batch and flow injection (FI) analysis, respectively, and (1.58 × 10−5)–(1.00 × 10−2) and (5.01 × 10−5)–(1.00 × 10−2) M in case of clobutinol-phosphomolybdate ((Clob)3-PM) for batch and FI analysis systems, respectively. The electrodes were successfully applied for the potentiometric determination of ClobCl in pharmaceutical preparation and urine in steady state and flow injection conditions. The electrodes exhibit good selectivity for Clob with respect to a large number of inorganic cations, sugars and amino acids.
Keywords :
Clobutinol hydrochloride , Ion-selective electrodes , Flow injection analysis , Potentiometry
Journal title :
Talanta
Serial Year :
2006
Journal title :
Talanta
Record number :
1649962
Link To Document :
بازگشت