Title of article :
Effect of cetyltrimethylammonium bromide on the migration of polyaromatic hydrocarbons in capillary electrokinetic chromatography
Author/Authors :
Belin، نويسنده , , G. Kavran and Erim، نويسنده , , F.B. and Gülaçar، نويسنده , , F.O.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2006
Abstract :
The separation of different ring numbered polyaromatic hydrocarbons (PAHs) was accomplished by using cetyltrimethylammonium bromide (CTAB) in capillary electrokinetic chromatography. In order to increase the solubilities and selectivities of PAHs, acetonitrile (ACN) was used as an organic modifier. Under the optimised conditions, 11 aromatic compounds were separated within 14.5 min in a running electrolyte containing 10 mM phosphate, 30 mM CTAB, and 40% ACN at pH 6.0. The effects of CTAB and ACN concentrations, voltage and pH on the resolution were investigated. Reproducibilities of migration times range between 0.55 and 1.27 R.S.D.% and peak areas between 1.02 and 7.23 R.S.D.%. Limit of detections (LODs) range between 0.09 and 2.24 μg ml−1. This new and fast separation method of PAHs was applied to cooked oil sample.
Keywords :
Capillary electrophoresis , PAHS , Cationic surfactant , Cooked oil , Cetyltrimethylammonium bromide