• Title of article

    Monoclonal antibody based electrochemical immunosensor for the determination of ochratoxin A in wheat

  • Author/Authors

    Alarcَn، نويسنده , , Sergio Hugo and Palleschi، نويسنده , , Giuseppe and Compagnone، نويسنده , , Dario and Pascale، نويسنده , , Michelangelo and Visconti، نويسنده , , Angelo and Barna-Vetrَ، نويسنده , , Ildikَ، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2006
  • Pages
    7
  • From page
    1031
  • To page
    1037
  • Abstract
    Competitive electrochemical enzyme-linked immunosorbent assays based on disposable screen-printed electrodes have been developed for quantitative determination of ochratoxin A (OTA). The assays were carried out using monoclonal antibodies in the direct and indirect format. OTA working range, I50 and detection limits were 0.05–2.5 and 0.1–7.5 μg L−1, 0.35 (±0.04) μg L−1 and 0.9 (±0.1) μg L−1, 60 and 100 μg L−1 in the direct and indirect assay format, respectively. The immunosensor in the direct format was selected for the determination of OTA in wheat. Samples were extracted with aqueous acetonitrile and the extract analyzed directly by the assay without clean-up. The I50 in real samples was 0.2 μg L−1 corresponding to 1.6 μg/kg in the wheat sample with a detection limit of 0.4 μg/kg (calculated as blank signal −3σ). Within- and between-assay variability were less than 5 and 10%, respectively. A good correlation (r = 0.9992) was found by comparative analysis of naturally contaminated wheat samples using this assay and an HPLC/immunoaffinity clean-up method based on the AOAC Official Method 2000.03 for the determination of OTA in barley.
  • Keywords
    Immunosensors , Ochratoxin A , Screen-printed electrodes , wheat , ELISA
  • Journal title
    Talanta
  • Serial Year
    2006
  • Journal title
    Talanta
  • Record number