Title of article :
Determination of clarithromycin in rat plasma by HPLC–UV method with pre-column derivatization
Author/Authors :
Li، نويسنده , , Wei and Jia، نويسنده , , Huijuan and Zhao، نويسنده , , Kang، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2007
Pages :
6
From page :
385
To page :
390
Abstract :
A novel high-performance liquid chromatographic (HPLC) method using pre-column derivatization and UV detection at 275 nm for the determination of clarithromycin in rat plasma has been validated. Clarithromycin was extracted from plasma sample spiked with internal standard (erythromycin) under alkaline condition with ethyl ether and derivatizated with trimethylbromosilane. The analyses were run on a C18 column, maintained at 40 °C during elution, using a mobile phase comprised of potassium dihydrogen phosphate (50 mM, pH 6.8, contained 0.7% triethylamine), acetonitrile, and methanol (30:45:25, v/v/v). The standard calibration curve for clarithromycin was linear (r2 = 0.9998) over the concentration range of 0.1–10 μg ml−1 in rat plasma. The limit of detection (LOD) and limit of quantitation (LOQ) was 30 ng ml−1 and 0.1 μg ml−1 respectively. The intra- and inter-day assay variability range was 2.6–7.4% and 3.3–8.5%, respectively. This method has been successfully applied to a pharmacokinetic study of clarithromycin in rats.
Keywords :
Derivatization , Clarithromycin , Trimethylbromosilane , High-performance liquid chromatography , Rat plasma
Journal title :
Talanta
Serial Year :
2007
Journal title :
Talanta
Record number :
1651156
Link To Document :
بازگشت