• Title of article

    Total internal reflected resonance light scattering determination of protein in human blood serum at water/tetrachloromethane interface with Arsenazo-TB and Cetyltrimethylammonium bromide

  • Author/Authors

    Dong، نويسنده , , Lijun and Chen، نويسنده , , Xingguo and Hu، نويسنده , , Zhide، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    555
  • To page
    560
  • Abstract
    A direct quantification of protein in human blood serum samples is proposed based on the measurement of total internal reflected resonance light scattering (TIR-RLS) at water/tetrachloromethane (H2O/CCl4) interfaces. At pH 4.10 and in the presence of Cetyltrimethylammonium bromide (CTAB), the interaction of Arsenazo-TB (ATB) with human serum albumin (HSA) results in strong enhanced TIR-RLS signals with the maximum spectra peak located at 330 nm. The enhanced TIR-RLS intensity at 330 nm was found to be proportional to the concentration of HSA in the range 0.5–42.3 μg/ml and its limit of determination (3σ) is 198 ng/ml. The content of HSA in blood serum samples were determined with the recovery of 97–103% for standard addition experiment.
  • Keywords
    Arsenazo-TB , Cetyltrimethylammonium bromide , Determination , Total internal reflected resonance light scattering , human serum albumin
  • Journal title
    Talanta
  • Serial Year
    2007
  • Journal title
    Talanta
  • Record number

    1651234