Title of article :
500 h Continuous aging life test on PBI/H3PO4 high-temperature PEMFC
Author/Authors :
Hu، نويسنده , , Jingwei and Zhang، نويسنده , , Huamin and Zhai، نويسنده , , Yunfeng and Liu، نويسنده , , Yong-gang and Yi، نويسنده , , Baolian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
8
From page :
1855
To page :
1862
Abstract :
500 h continuous aging test on high-temperature PEMFC (phosphoric acid-doped PBI system) was conducted, steady-state performance (current density = 640 mA cm - 2 ) was recorded, polarization curves were tested every 24 h, and electrochemical techniques—cyclic voltametry (CV) and electrochemical impedance spectroscopy (EIS)—were used to study the relationship between electrochemical surface area (ESA), internal resistance ( R in ) and charge transfer resistance ( R ct ) with time. Our research results showed that after about 100 h activation, the cell performance began to degrade, and the cell voltage degradation rate is about 150 μ V h - 1 at 640 mA cm - 2 . AC impedance measurements showed that there was no obvious membrane degradation for internal resistance remains almost stable. The main reason for performance degradation is the decrease of ESA and the increase of R ct , which implied that obvious degradation occurs at catalyst.
Keywords :
High-temperature PEMFC , PBI/H3PO4 , internal resistance , Performance degradation , Voltage degradation
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2006
Journal title :
International Journal of Hydrogen Energy
Record number :
1651495
Link To Document :
بازگشت