Title of article :
Voltammetric determination of anabolic steroid nandrolone at gold nanoparticles modified ITO electrode in biological fluids
Author/Authors :
Goyal، نويسنده , , Rajendra N. and Oyama، نويسنده , , Munetaka and Tyagi، نويسنده , , Anuradha and Singh، نويسنده , , Sudhanshu P.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2007
Pages :
5
From page :
140
To page :
144
Abstract :
The electrochemical behavior of nandrolone decanoate (ND) at gold nanoparticles modified indium tin oxide (ITO) electrode was investigated. Oxidation of ND has been carried out in phosphate containing supporting electrolyte in the pH range 2.1–9.2 and a well-defined oxidation peak was noticed. The peak potential (Ep) of the oxidation peak decreases linearly with increasing pH. Linear calibration curve is obtained over the nandrolone decanoate concentration range of 50 nM to 1.5 μM at pH 7.2 with a detection limit of 1.36 × 10−7 M. The proposed method is effectively applied to detect the concentration of ND in human blood serum and urine samples after 24 and 72 h of intramuscular injection. The method is rapid and does not require any pre-treatment.
Keywords :
Nandrolone decanoate , Voltammetric detection , Biological fluids , Gold nanoparticles modified ITO electrode
Journal title :
Talanta
Serial Year :
2007
Journal title :
Talanta
Record number :
1652019
Link To Document :
بازگشت