Title of article
Remote optical fibre microsensor for monitoring BTEX in confined industrial atmospheres
Author/Authors
Silva، نويسنده , , Lurdes I.B. and Rocha-Santos، نويسنده , , Teresa A.P. and Duarte، نويسنده , , A.C.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2009
Pages
5
From page
548
To page
552
Abstract
A portable optical fibre sensor has been developed for remote monitoring of benzene, toluene, ethylbenzene, p-xylene, m-xylene and o-xylene (BTEX). Firstly, the analyser was tested for calibration and its analytical performance for BTEX monitoring compared with a more classical analytical method, namely gas chromatography coupled to a flame ionization detector (GC-FID). The developed remote sensor shows several analytical advantages such as, high analytical sensitivity and accuracy, good linearity and stability of the analytical signal and short analytical time. Secondly, the optical fibre based sensor was applied to air monitoring for detection and quantification of BTEX in a confined industrial environment. The analytical signal measurement was performed by wireless at 20 m of distance from the local of analysis. Besides, the reported sensor showed a high degree of portability, compact design and high analytical performance for remote BTEX monitoring, in situ and in real-time.
Keywords
BTEX detection , Optical fibre sensing , Confined atmospheres monitoring , Real-time analysis