Title of article :
Highly selective preconcentration of Cu(II) from seawater and water samples using amidoamidoxime silica
Author/Authors :
Ngeontae، نويسنده , , Wittaya and Aeungmaitrepirom، نويسنده , , Wanlapa and Tuntulani، نويسنده , , Thawatchai and Imyim، نويسنده , , Apichat، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2009
Pages :
7
From page :
1004
To page :
1010
Abstract :
Chemically modified silica containing amidoamidoxime group was studied as a sorbent for solid-phase extraction (SPE) and preconcentration of Cu(II) prior to determination by flame atomic absorption spectrometry (FAAS). The sorbent showed an extremely high selectivity towards Cu(II) in the pH range of 4–6, while the extraction of Pb(II), Cd(II), Ni(II) and Co(II) was low. The adsorption isotherm followed the Langmuir model and the maximum sorption capacity of 0.0163 mmol Cu(II) g−1 was achieved. In the flow system, Cu(II) was completely retained on a column containing 40 mg of the modified silica at the flow rate of 4.0 mL min−1 and quantitatively eluted by 5 mL of 1% (v/v) HNO3. No interference from Na+, K+, Mg2+, Ca2+, Cl− and SO42− at 10, 100 and 1000 mg L−1 was observed. When applied for preconcentration and determination of Cu(II) in tap water, pond water, and seawater, the recoveries were 96, 101, and 95%, respectively, with high precision (% relative standard deviation (R.S.D.) < 4) and low method detection limit (9 μg L−1).
Keywords :
Amidoamidoxime , silica , Copper , Preconcentration , FAAS