• Title of article

    Online humidification diagnosis of a PEMFC using a static DC–DC converter

  • Author/Authors

    Hinaje، نويسنده , , M. and Sadli، نويسنده , , I. and Martin، نويسنده , , J.-P. and Thounthong، نويسنده , , P. and Raël، نويسنده , , S. and Davat، نويسنده , , B.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    6
  • From page
    2718
  • To page
    2723
  • Abstract
    This paper deals with the online checking of the humidification of a Proton Exchange Membrane Fuel Cell (PEMFC). Indeed, drying or flooding can decrease the performance of the PEMFC and even lead to its destruction. An online humidification diagnosis can allow a real-time control. A good indicator of the membrane humidification state is its internal resistance. As known, the membrane ionic conductivity increases with the membrane water content. This resistance can be calculated at high frequency by dividing the voltage variation by the current variation. The proposed scheme makes use of measurements of current and voltage ripples coming from the association of a static DC–DC converter and the fuel cell. The experiment thus consists in computing the internal resistance in wet and dry conditions.
  • Keywords
    Proton exchange membrane fuel cell , Membrane resistance , Boost converter , Diagnosis Humidification
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2009
  • Journal title
    International Journal of Hydrogen Energy
  • Record number

    1657414