• Title of article

    Robust hydrogen detection system with a thermoelectric hydrogen sensor for hydrogen station application

  • Author/Authors

    Nishibori، نويسنده , , M. and Shin، نويسنده , , W. and Izu، نويسنده , , N. and Itoh، نويسنده , , T. and Matsubara، نويسنده , , I. and Yasuda، نويسنده , , S. and Ohtani، نويسنده , , S.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    8
  • From page
    2834
  • To page
    2841
  • Abstract
    A prototype hydrogen detection system using the micro-thermoelectric hydrogen sensor (micro-THS) was developed for the safety of hydrogen infrastructure systems, such as hydrogen stations. We have designed a detection part with a pressure proof enclosure adoptable for the international standard of Exd II CT3, and carried out an explosion strength test, explosion and fire hazard tests, and an impact test. The hydrogen sensing performance of the detection part of this prototype system showed a good linear relationship between the sensing signal and hydrogen concentrations in air, for a wide range of hydrogen concentrations from 10 ppm to 40,000 ppm (4 vol.%). This prototype detection system was installed in the outdoor field of the hydrogen station and the response for H2 gas in air of 100 ppm, 1000 ppm, and 10000 ppm was tested monthly for 1 year.
  • Keywords
    Prototype system , Thermoelectric hydrogen sensor , Hydrogen station , field test
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2009
  • Journal title
    International Journal of Hydrogen Energy
  • Record number