Title of article :
An interlaboratory study as useful tool for proficiency testing of chemical oxygen demand measurements using solid substrates and liquid samples with high suspended solid content
Author/Authors :
Raposo، نويسنده , , F. Javier de la Rubia، نويسنده , , M.A. and Borja، نويسنده , , R. and Alaiz، نويسنده , , M. and Beltrلn، نويسنده , , J. and Cavinato، نويسنده , , C. and Clinckspoor، نويسنده , , M. and Demirer، نويسنده , , G. and Diamadopoulos، نويسنده , , E. and Helmreich، نويسنده , , B. and Jenicek، نويسنده , , P. and Martي، نويسنده , , N. and Méndez، نويسنده , , R. and Noguerol، نويسنده , , J. and Pereira، نويسنده , , Harry F. and Picard، نويسنده , , S. and Torrijos، نويسنده , , M.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2009
Pages :
9
From page :
329
To page :
337
Abstract :
In 2008, the first Proficiency Testing Scheme of Chemical Oxygen Demand (1st COD-PTADG) was conducted to assess the results obtained for different research groups whose field work is mainly anaerobic digestion. This study was performed using four samples, two solid samples as raw materials and two solid samples to prepare high concentration suspended solid solutions. Invitations were sent to a large number of laboratories, mainly to anaerobic digestion research groups. Finally, thirty labs from sixteen countries agreed to participate, but for different reasons four participants could not send any data. In total, twenty-six results were reported to the COD-PT coordinator. tudy showed the importance of continuous participation in proficiency testing (PT) schemes in order to compare the results obtained. Taking into account the lack of a general standard method and high quality certified reference materials (CRMs), the traceability of COD determination is not currently easy to check. In addition, the spread of participants’ results obtained was high and pointed to the advisability of using consensus values due to their unreliability. Therefore, the theoretical oxygen demand (ThOD) values were considered as assigned values for all the samples analysed. On the other hand, in this PT the established standard deviation (ESD) has been determined by the Horwitz modified function. ipants of this 1st COD-PTADG were asked to give a short report on the analytical method used. Although all the participants used potassium dichromate as their oxidant reagent, their experimental procedures were very different. With the purpose of comparing the results obtained, the different experimental conditions used were classified into five methods, corresponding to two main categories, open and closed reflux. The performance of laboratories was expressed by the z-score, whose value is considered satisfactory when z-score ≤±2. The overall analytical data evaluation showed that 64% of z-scores obtained were outside the accepted limits.
Keywords :
Interlaboratory study , proficiency testing , Chemical oxygen demand , Anaerobic digestion , Suspended Solids , Homogeneity test , Solid substrate
Journal title :
Talanta
Serial Year :
2009
Journal title :
Talanta
Record number :
1658850
Link To Document :
بازگشت