Title of article :
Determination of volatile organic compounds in contaminated air using semipermeable membrane devices
Author/Authors :
Francesc A. and Ly-Verdْ، نويسنده , , Saray and Esteve-Turrillas، نويسنده , , Francesc A. and Pastor، نويسنده , , Agustيn and de la Guardia، نويسنده , , Miguel، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2010
Pages :
8
From page :
2041
To page :
2048
Abstract :
Semipermeable membrane devices (SPMDs) were evaluated as passive samplers for the determination of 26 volatile organic compounds (VOCs) in contaminated air of occupational environments. A direct methodology based on the use of head-space-gas chromatography–mass spectrometry (HS-GC–MS) was developed for VOCs determinations in SPMDs, without any sample pre-treatment and avoiding the use of solvents. A desorption temperature of 150 °C for 10 min was sufficient for a sensitive VOCs determination providing limits of detection in the range of 15 ng SPMD−1 for 21 of 26 studied compounds. Linear and equilibrium uptake models were established for each VOC from compound isotherms. Highly volatile compounds were slightly absorbed and moderately volatile compounds were strongly absorbed by SPMDs. This study is the first precedent of the use of SPMDs for the simultaneous sampling of a wide number of VOCs. The use of SPMDs is a simple and low cost alternative to ordinary sampling devices such as Radiello® diffusive samplers or badge-type solid-phase supports.
Keywords :
VOCS , SPMDs , Air passive sampling , Head-space , Radiello®
Journal title :
Talanta
Serial Year :
2010
Journal title :
Talanta
Record number :
1659707
Link To Document :
بازگشت