Title of article :
Correlation between different clean-up methods and analytical techniques performances to detect Ochratoxin A in wine
Author/Authors :
Fabiani، نويسنده , , Alessandra and Corzani، نويسنده , , Claudia and Arfelli، نويسنده , , Giuseppe، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2010
Pages :
5
From page :
281
To page :
285
Abstract :
Three different clean-up methods and two analytical techniques were compared to determine Ochratoxin A (OTA) in wines. The first clean-up used a MycoSep column, the second an immunoaffinity column (IAC) and the third consisted in a liquid–liquid extraction (LLE) using dichloromethane in acid conditions. Meanwhile, two different OTA determination techniques were also evaluated: a HPLC analysis using a fluorescence detector and an enzyme-linked immunosorbent assays (ELISA) method. ations between clean-up methods and analytical techniques to determine OTA in wine were made evaluating linearity, accuracy and precision. he two first clean-up methods (solid-phase extraction, SPE) showed a good linear fit (r2 = about 0.9999), followed by LLE. The use of immunoaffinity columns showed the best recoveries, even if also the SPE with MycoSep showed good recoveries while the LLE recoveries were the worst ones. The HPLC analysis showed good precision and accuracy, while ELISA method, even with a sufficient linearity, generally underestimated OTA content in wines.
Keywords :
Wine , ELISA , Sample clean-up , Ochratoxin A , SPE , Immunoaffinity columns , LLE , HPLC
Journal title :
Talanta
Serial Year :
2010
Journal title :
Talanta
Record number :
1661104
Link To Document :
بازگشت