Title of article :
Cellulose microfiber functionalized with N,N′-bis (2-aminoethyl)-1,2-ethanediamine as a solid sorbent for the fast preconcentration of Cd(II) in flow system analysis
Author/Authors :
de Oliveira، نويسنده , , Fernanda Midori and Somera، نويسنده , , Bruna Fabrin and Corazza، نويسنده , , Marcela Zanetti and Yabe، نويسنده , , Maria Josefa Santos and Segatelli، نويسنده , , Mariana Gava and Ribeiro، نويسنده , , Emerson Schwingel and Lima، نويسنده , , ةder Clلudio and Dias، نويسنده , , Silvio Luيs Pereira and Tarley، نويسنده , , César Ricardo Teixeira، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2011
Pages :
8
From page :
2417
To page :
2424
Abstract :
The present paper describes the synthesis of a new chemically modified cellulose microfiber through oxidation with sodium periodate and functionalization with N,N′-bis (2-aminoethyl)-1,2-ethanediamine for the fast and selective preconcentration of Cd(II) ions in flow system analysis. The new sorbentsorbent was characterized by FTIR, SEM, and surface area values. The uptake behavior of Cd(II) ions onto this sorbent was evaluated from kinetic data, pseudo-first-order and pseudo-second-order models, as well as from Langmuir, Freundlich and Langmuir–Freundlich adsorption isotherms. The maximum sorption capacity of 4.59 mg g−1 was estimated by the Langmuir–Freundlich model with fast kinetics for the sorption of Cd(II) described by the pseudo-second-order kinetic model. After characterization, the sorbent was packed in a mini-column, and a fast flow injection preconcentration system for Cd(II) determination by FAAS was developed. The best Cd(II) preconcentration condition, obtained by means of factorial design and response surface methodology, was achieved at pH 9.36 and a flow rate of 10 mL min−1 followed by elution with 1.0 mol L−1 nitric acid. By using 78 s preconcentration time, fast and highly sensitive determination of Cd(II) ions could be achieved with a limit of quantification of 0.20 μg L−1, preconcentration factor of 26, consumption index of 0.5 mL, concentration efficiency of 20 min−1, and sample throughput of 39 h−1. The repeatability for 10 replicate determinations was found to be 7.8 and 2.5% for Cd(II) ion concentrations of 5.0 and 100.0 μg L−1, respectively. The new sorbent efficiency for the interference-free preconcentration of Cd(II) ions was assessed by analysis of tap, mineral and lake waters, as well as synthetic seawater and normal saline waters. Furthermore, complex samples, such as biological samples, could be analysed by the proposed method in accordance with the accuracy attested by analysis of certified reference materials, TORT-2 (lobster hepatopancreas), and DOLT-4 (dogfish liver).
Keywords :
Modified cellulose microfiber , Preconcentration , Factorial design , Cadmium
Journal title :
Talanta
Serial Year :
2011
Journal title :
Talanta
Record number :
1663438
Link To Document :
بازگشت