Title of article :
Polymer modified glassy carbon electrode for the electrochemical determination of caffeine in coffee
Author/Authors :
Amare، نويسنده , , Meareg and Admassie، نويسنده , , Shimelis، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2012
Pages :
7
From page :
122
To page :
128
Abstract :
4-Amino-3-hydroxynaphthalene sulfonic acid (AHNSA) was electropolymerized on a glassy carbon electrode. The deposited film showed electrocatalytic activity towards the oxidation of caffeine. The polymer-modified electrode showed high sensitivity, selectivity and stability in the determination of caffeine in coffee. The peak current increased linearly with the concentration of caffeine in the range of 6 × 10−8 to 4 × 10−5 mol L−1, with a detection limit of 1.37 × 10−7 mol L−1 (LoD = 3δ/slope). Analysis of caffeine in coffee was affected neither by sample matrices nor by structurally similar compounds. Recoveries ranging between 93.75 ± 2.32 and 100.75 ± 3.32 were achieved from coffee extracts indicating the applicability of the developed method for real sample analyses.
Keywords :
caffeine , 4-Amino-3-hydroxynaphthalene sulfonic acid , Square Wave Voltammetry , Coffee , Cyclic voltammetry