Title of article :
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Author/Authors :
Darowicki، نويسنده , , Slepski، Pawel نويسنده Gdansk University of Technology, Department of Electrochemistry, Corrosion & Materials Engineering, PL-80952 Gdansk, Poland , , P، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
7
From page :
25
To page :
31
Abstract :
Impedance measurements on a new, model RC electrical circuit have been conducted with the use of a continuous frequency scanning method. The impedance of the model circuit was determined for different types and sizes of the analyzing window. The values of the resistance and capacitance parameters obtained for different analyzing windows were compared with their true values. The influence of the type and length of analyzing window on the accuracy of the results has been recognized.
Keywords :
instantaneous frequency , Chirp signal , Analyzing windows , Electrochemical impedance spectroscopy , Short time Fourier transformation