Title of article
Rapid and selective determination of free chlorine in aqueous solution using electrophilic addition to styrene by gas chromatography/mass spectrometry
Author/Authors
Wakigawa، نويسنده , , Akinaga and Fukushima، نويسنده , , Sunao and Mori، نويسنده , , Takeshi and Niidome، نويسنده , , Takuro and Katayama، نويسنده , , Yoshiki، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2013
Pages
5
From page
81
To page
85
Abstract
We developed a rapid and selective method for determination of free chlorine in aqueous solution by gas chromatography/mass spectrometry for the first time. Free chlorine was converted to styrene chlorohydrin using electrophilic addition to styrene in sodium acetate buffer solution (pH 5). The chlorine derivative obtained was extracted with chloroform, and then analyzed by GC/MS. The calibration curve showed good linearity from 0.2–100 μg/mL (as available chlorine). The detection limit was 0.1 μg/mL, and the intra- and interday accuracy were measured at concentrations of 10, 50, and 75 μg/mL to be −1.3 to 6.9% (intraday) and 3.8–8.0% (interday) as % Bias. The precision was between 1.4 and 4.5% as % RSD. These results indicate that this method is a superior technique for the identification of free chlorine. This method was successfully applied to quantification in commercial samples and in samples of a criminal case.
Keywords
GC/MS , Free chlorine , Electrophilic addition , Forensic science , Chlorohydrin
Journal title
Talanta
Serial Year
2013
Journal title
Talanta
Record number
1666584
Link To Document