Title of article
Relaxation and Simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments
Author/Authors
Flexer، نويسنده , , V. and Pratt، نويسنده , , K.F.E. and Garay، نويسنده , , F. Michael Bartlett، نويسنده , , P.N. and Calvo، نويسنده , , E.J.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
12
From page
87
To page
98
Abstract
A description of the implementation of the relaxation method with automatic mesh point allocation for immobilized enzyme electrodes is presented. The advantages of this method for the solution of coupled reaction–diffusion problems are discussed. The relaxation numerical simulation technique is combined with the Simplex fitting algorithm to extract kinetic parameters from experimental data. The results of the simulations are compared to experimental data from self-assembled multilayered electrodes comprised of glucose oxidase (GOx) and an Os modified redox mediator and found to be in excellent agreement.
Keywords
Relaxation Method , Simplex algorithm , Enzyme electrodes , Electrostatic self-assembly
Journal title
Journal of Electroanalytical Chemistry
Serial Year
2008
Journal title
Journal of Electroanalytical Chemistry
Record number
1666795