• Title of article

    Accelerated anode failure of a high temperature planar SOFC operated with reduced moisture and increased PH3 concentrations in coal syngas

  • Author/Authors

    De Silva، نويسنده , , K. Channa R. and Kaseman، نويسنده , , Brian J. and Bayless، نويسنده , , David J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    11
  • From page
    9945
  • To page
    9955
  • Abstract
    Electrolyte supported SOFCs with Ni-YSZ/Ni-GDC bi-layer anodes were operated at 800 °C and 900 °C with 8% H2O and 10–20 ppm of PH3/syngas to reduce steam-related interference accelerate degradation. Cell power output degraded rapidly within the first 12 h, with even faster degradation at 900 °C. Nickel phosphide phases detected in the anode include Ni3P, Ni12P5 and Ni5P2, while CePO4 formed in the catalyst layer. Irrespective of the electrolyte component used, phosphorus penetrated to the anode–electrolyte interface in electrically loaded cells, as well as with Ni-GDC cells in coupon tests. In contaminated bi-layer anodes, phosphorus appeared to concentrate away from the surface, suggesting oxidation of PH3 when steam rich environments were present.
  • Keywords
    PH3 contaminated syngas , Solid oxide fuel cells (SOFCs) , Anode poisoning
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2011
  • Journal title
    International Journal of Hydrogen Energy
  • Record number

    1666871