Title of article :
Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity
Author/Authors :
Zhang، نويسنده , , Zhen and Wang، نويسنده , , Zheng and Li، نويسنده , , Qing-Qing Zou، نويسنده , , Huijun and Shi، نويسنده , , Ying، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2014
Pages :
7
From page :
613
To page :
619
Abstract :
Solution cathode glow discharge-atomic emission spectrometry (SCGD-AES) was evaluated for its ability to determine toxic heavy metals, including cadmium (Cd), mercury (Hg), lead (Pb), and chromium (Cr), in environmental and biological samples. A significant enhancement in heavy metal signal was observed by addition of a small amount of cetyltrimethylammoniumchloride (CTAC, C16H33 (CH3)3NCl) to the samples. The net intensity of atomic emission lines of Cd, Hg, Pb, and Cr increased by 2.1-, 4.8-, 6.6-, and 2.6-fold, respectively, after addition of 0.15% CTAC to the test solutions. The effects of ionic surfactants (CTAC) compared with non-ionic surfactants, e.g., Triton x-45 and Triton x-100, on the sensitivity of Cd, Hg, Pb, and Cr were also investigated in the present study. The enhancement effect is in the order Triton x-45<Triton x-100<CTAC for Hg, Pb and Cr and Triton x-45<CTAC<Triton x-100 for Cd. Addition of CTAC to the electrolyte solutions decreased the background intensity and fluctuation of atomic emission lines of studied metals. It also changed the surface tension and the viscosity, and increased average discharge current of electrolyte solution. SCGD sensitivity to the heavy metals greatly improved by addition of the surfactant. The improved detection limits of Cd, Hg, Pb, and Cr were 1.0, 7.0, 2.0, and 42 ng mL−1, respectively. The proposed method was validated by quantifying Cd, Hg, Pb, and Cr in certified reference materials, including human hair (GBW 09101b) and stream sediment (GBW 07310 and GBW07311). Measurement results obtained for the determination of Cd, Hg, Pb, and Cr in the reference materials agreed well with reference values. This study improves the application of SCGD-AES in quantifying very low levels of Cd, Hg, Pb, and Cr from biological and environmental materials.
Keywords :
Heavy metals , Solution cathode glow discharge-atomic emission spectrometry , Cetyltrimethylammoniumchloride , Environmental and biological samples
Journal title :
Talanta
Serial Year :
2014
Journal title :
Talanta
Record number :
1670019
Link To Document :
بازگشت