Abstract :
A procedure for sizing an electrolytic hydrogen production plant powered by a stand-alone photovoltaic system is described in this study. Our fundamental proposal is to compensate the loss of load probability of the photovoltaic system, by means of a hydrogen complementary storage. We compute the necessary hydrogen volume of that reserve storage. Using the isoreliability map of curves that characterizes a given location, we determine the size of the photovoltaic system that would be needed to generate a predetermined flow of hydrogen. Finally, we share information on our own experience relating to the design of the experimental installation at Villafrيa, located in the city of Burgos, Spain.
Keywords :
Renewable energy sources , Photovoltaic systems , Hydrogen production , Optimal design , Stand-alone power systems