Title of article :
Performance analysis of HT-PEFC stacks
Author/Authors :
Lüke، نويسنده , , Lukas and Jan?en، نويسنده , , Holger and Kvesi?، نويسنده , , Mirko and Lehnert، نويسنده , , Werner and Stolten، نويسنده , , Detlef، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
11
From page :
9171
To page :
9181
Abstract :
The performance analysis of a five-cell HT-PEFC stack is presented. The stack was operated either with pure hydrogen or synthetic reformate on the anode side and air on the cathode side. The overall electric performance and the heat management were analyzed. The local performance was assessed by current density and temperature distribution measurements. For this purpose, a tailor-made measuring board was integrated into the stack assembly. It is shown how the choice of fuel gas composition, reactant stoichiometry, flow direction and cooling affect the current density and temperature distribution.
Keywords :
HT-PEFC , Stack , Current density distribution , Temperature distribution , Reformate
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2012
Journal title :
International Journal of Hydrogen Energy
Record number :
1671819
Link To Document :
بازگشت