Title of article
Anode water removal and cathode gas diffusion layer flooding in a proton exchange membrane fuel cell
Author/Authors
Anderson، نويسنده , , Ryan and Blanco، نويسنده , , Mauricio and Bi، نويسنده , , Xiaotao and Wilkinson، نويسنده , , David P.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
11
From page
16093
To page
16103
Abstract
Anode water removal (AWR) is studied as a diagnostic tool to assess cathode gas diffusion layer (GDL) flooding in PEM fuel cells. This method uses a dry hydrogen stream to remove product water from the cathode, showing ideal fuel cell performance in the absence of GDL mass transfer limitations related to water. When cathode GDL flooding is limiting, the cell voltage increases as the hydrogen stoichiometry is increased. Several cathode GDLs were studied to determine the effect of microporous layer (MPL) and PTFE coating. The largest voltage gains occur with the use of cathode GDLs without an MPL since these GDLs are prone to higher liquid water saturation. Multiple GDLs are studied on the cathode side to exacerbate GDL flooding conditions to further confirm the mechanism of the AWR process. Increased temperature and lower cathode RH allow for greater overall water removal so the voltage improvement occurs faster, though this leads to quicker membrane dehydration.
Keywords
Water management , GDL flooding , Anode water removal , PEM fuel cells
Journal title
International Journal of Hydrogen Energy
Serial Year
2012
Journal title
International Journal of Hydrogen Energy
Record number
1673599
Link To Document