Title of article :
PEFC-type impurity sensors for hydrogen fuels
Author/Authors :
Noda، نويسنده , , Z. and Hirata، نويسنده , , K. and Hayashi، نويسنده , , A. and Taniguchi، نويسنده , , S. and Nakazato، نويسنده , , N. and Seo، نويسنده , , A. and Yasuda، نويسنده , , I. and Ariura، نويسنده , , S. and Shinkai، نويسنده , , H. and Sasaki، نويسنده , , K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
16256
To page :
16263
Abstract :
Hydrogen purity sensor cells were newly developed with the principle of PEFC. By using the phenomena of PEFCʹs voltage drop seen in the presence of impurities and further minimizing the amount of Pt to make the cells more sensitive to impurities, the sensor cells were prepared. This unique sensing principle was applied to typical impurities in practical hydrogen gases, including CO, H2S, and NH3. Sensor responses were derived by analyzing various kinds of dependency on Pt loading, current density, impurity concentration, and operational temperature. Possibility of recovery from impurity poisoning was also studied by varying impuritiesʹ supply and potential charge. Consequently, our simple PEFC-type hydrogen purity sensors were verified to have ability to sense ppm-level impurities within 10 min.
Keywords :
Sensor , impurity , PEFC , CO , H2S , NH3
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2012
Journal title :
International Journal of Hydrogen Energy
Record number :
1673629
Link To Document :
بازگشت